DiGi Start Pro VS Voice Multi Control - Comparison chart
Overview
Advanced digital control system with plenty of functions for the geeks that want to have total overview and control and want to see all the measured values.
You can also set the clock, timed startup or timed shut down.
The LED Screen automatically goes to sleep mode after short time of inactivity which is handy during the night.
The wired switch comes with the advanced wireless controller with the LCD display allowing you to have direct feedback of your remote operations. You can also link a keychain controller (optional) in case you wish the remote always with you.
This control system has been designed as an answer for all people who were long time looking for the most intuitive control system of diesel air heater with straightforward and fastest user interface and still keeping the UI fully digital.
With its only one indefinite rotating knob you will be able to perform all the operations and adjust the heating power or the temperature in a fraction of second.
The beautiful colour screen shows just the most important information and you can stay focused on your another every day tasks. If you need to browse the menu, the English voice-over will help you to navigate thru. The sound can be also turned off for the most quiet operation.
The wired switch comes with the wireless keychain controller allowing fully remote operations.
The best advantage is the auto-stop function that allows the full shut-down of the unit and prevents overheating of the heated space.
Advantages
LCD Wireless Controller
Clock & Timer
Displayed values
Display sleep mode
Simplicity & Super-fast operation
Auto-stop function
Ventilation mode
Voice-over
Fixed power mode
YES
YES
Heating power range
1kW - 2kW (2kW model)
1kW – 5kW (5kW model)
1kW - 2kW (2kW model)
1kW – 5kW (5kW model)
Thermostatic mode
The thermostatic mode automatically regulates the heating power within the range of minimal and maximal values depending on the selected temperature.
YES
YES
Temperature range
+8 ̊C to +35 ̊C
+10 ̊C to +35 ̊C
Auto-stop function
N/A
The heating unit continues heating in the lowest heating power once the preset temperature is reached. This can cause increasing of the room temperature above the preset temperature.
YES
The controller allows full shut-down of the heating process after reaching the preset temperature to avoid overheating of the heated space. The unit waits fully off and innitiates the next heating cycle again once the room temperature drops couple of degees below preset temperature
* The auto-stop function of the thermostatic mode IS NOT nequired if:
1) The heated space is enough large or the large heat loss does not allow any overheating over the limit of comfortable temperature during the lowest power.
2) The heated space allows a ventilation of the residual heat thru the ceiling or the side windows out to the exterior.
3) The suction of the cold air to the heater unit is intentionally connected to exterior to drop the input/output temperature of air.
3) The capacity of the battery is very limited and you can not risk discharging a battery by high power consumption caused by sequential startup and shutdown.
4) The heater unit is used only for short period to preheat the space and than is manually switched off.
* The auto-stop function of the thermostatic mode IS nequired if:
1) The application requires a stable room temperature no matter of conditions.
Ventilation mode
Allows creating regulated flow of the air without heating process which is handy during summer months.
N/A
YES
Speed range
N/A
1000 RPM - 4500 RPM
Manual fuel filling mode
This mode is used after the first installation of the unit or if the unit shuts down because the fuel tank ran out of thediesel.
YES
YES
Pumping frequency
-
6 Hz
Pumping flow
-
7.92ml / minute (5kW version)
Auto-ignition
N/A
The fuel pumping mode can only be done while the fuel line is disconnected from the heater unit or you visually control the position of the diesel on the transparent fuel line.
You must manually stop this mode before the fuel reaches the fuel inlet of the heating unit, otherwise the burner will be fulfilled with the fueland the next startup will be unsuccessful.
YES
The fuel pumping mode is fully automatic with extra high frequency allowing to prime the fuel line quickest possible.
As the heater unit automatically activates the glow plug before innitiating the fuel pumping mode there is no risk of overfilling the heater unit.
Clock & Timer
Clock
YES
N/A
Timed startup
YES
Countdown set in relative values of hours and minutes
N/A
Timed shut-down
YES
Countdown set in relative values of hours and minutes
N/A
Voice-over
N/A
YES
Modes
N/A
Voice
Beep
Quiet mode
Language of voice mode
N/A
English
Chinese
Russian
Display
Display
Super brigh colour
graphical LED display
Super bright colour
graphical LCD display
Sleep mode
YES
N/A
Displayed values
Heating power
YES
(represented as pump frequency)
YES
Preset temperature
YES
YES
Error codes
YES
YES
Room temperature
YES
N/A
Heat exchanger temperature
YES
N/A
Voltage
YES
N/A
Altitude
YES
N/A
Status icons
Fan
YES
YES
Glow Plug
YES
YES
Fuel Pump
YES
YES
Combustion
YES
YES
Wireless controller
YES
YES
Timer
YES
N/A
Altitude adjustment
Pressure sensor allows autamatic djustment of the amount of the oxygen based on the altitude. This allows operating the heating unit up to 4000metres from sea level.
YES
YES
Technical specifications
User interface
3 buttons
Indefinite digital rotating knob with button
Speaker
N/A
YES
Temperature sensor
YES
YES
Connector
Round 3pin waterproof connector
Round 3pin waterproof connector
Hidden cords
YES
* going downwards OR backwards
N/A
* going downwards
Dimensions
Height
2.36 inches (60 mm)
1.89 inches (48 mm)
Width
3.07 inches (78 mm)
2.87 inches (73 mm)
Depth
0.59 inches (15 mm)
1.06 inches (27 mm)
Keychain wireless controller
YES
(optional)
* can be ordered separatelly
YES
(included)
Modes
Start up / Shut down
YES
YES
Fixed power mode adjustment
YES
YES
Thermostatic mode adjustment
YES
YES
Specifications
User interface
4 buttons
4 buttons
Connection
Radio communication
Radio communication
LCD wireless controller
YES
(included)
N/A
Modes
Start up / Shut down
YES
N/A
Fixed power mode adjustment
YES
N/A
Thermostatic mode adjustment
YES
N/A
Displayed VALUES
Heating power
YES
(represented as pump frequency)
N/A
Preset temperature
YES
N/A
Altitude
YES
N/A
Error codes
YES
N/A
Voltage
YES
N/A
Status icons
Fan
YES
N/A
Heat exchanger temperature
YES
N/A
Specifications
Display
Graphical colour LCD display
N/A
User interface
4 buttons
N/A
Language
English
Chinese
N/A
Connection