DiGi Start Pro VS Voice Multi Control - Comparison chart


DiGI Start Pro
 

Click here to see complete operational manual.

 

Voice Multi Control

 

Click here to see complete operational manual.

 

Overview

 

Advanced digital control system with plenty of functions for the geeks that want to have total overview and control and want to see all the measured values.


You can also set the clock, timed startup or timed shut down.


The LED Screen automatically goes to sleep mode after short time of inactivity which is handy during the night.


The wired switch comes with the advanced wireless controller with the LCD display allowing you to have direct feedback of your remote operations. You can also  link a keychain controller (optional) in case you wish the remote always with you.



This control system has been designed as an answer for all people who were long time looking for the most intuitive control system of diesel air heater with straightforward and fastest user interface and still keeping the UI fully digital. 


With its only one indefinite rotating knob you will be able to perform all the operations and adjust the heating power or the temperature in a fraction of second.


The beautiful colour screen shows just the most important information and you can stay focused on your another every day tasks. If you need to browse the menu, the English voice-over will help you to navigate thru. The sound can be also turned off for the most quiet operation.


The wired switch comes with the wireless keychain controller allowing fully remote operations.


The best advantage is the auto-stop function that allows the full shut-down of the unit and prevents overheating of the heated space.


Advantages

LCD Wireless Controller

Clock & Timer

Displayed values

Display sleep mode

 

Simplicity & Super-fast operation

Auto-stop function

Ventilation mode

Voice-over

 

Fixed power mode

 

YES


 

YES


 

Heating power range

1kW - 2kW (2kW model)

1kW – 5kW (5kW model)

 

1kW - 2kW (2kW model)

1kW – 5kW (5kW model)

 

Thermostatic mode

 

The thermostatic mode automatically regulates the heating power within the range of minimal and maximal values depending on the selected temperature.

 

YES


 

YES


 

Temperature range

+8 ̊C to +35 ̊C

 

+10 ̊C to +35 ̊C

 

Auto-stop function

N/A


 

The heating unit continues heating in the lowest heating power once the preset temperature is reached. This can cause increasing of the room temperature above the preset temperature.

 

YES


 

The controller allows full shut-down of the heating process after reaching the preset temperature to avoid overheating of the heated space. The unit waits fully off and innitiates the next heating cycle again once the room temperature drops couple of degees below preset temperature

 

The auto-stop function of the thermostatic mode IS NOT nequired if:


1) The heated space is enough large or the large heat loss does not allow any overheating over the limit of comfortable temperature during the lowest power.

2) The heated space allows a ventilation of the residual heat thru the ceiling or the side windows out to the exterior.

3) The suction of the cold air to the heater unit is intentionally connected to exterior to drop the input/output temperature of air.

3) The capacity of the battery is very limited and you can not risk discharging a battery by high power consumption caused by sequential startup and shutdown.

4) The heater unit is used only for short period to preheat the space and than is manually switched off.


The auto-stop function of the thermostatic mode IS nequired if:


1) The application requires a stable room temperature no matter of conditions.




 

Ventilation mode

 

Allows creating regulated flow of the air without heating process which is handy during summer months.

 

N/A


 

YES


 

Speed range

N/A

 

1000 RPM - 4500 RPM

 

Manual fuel filling mode

 

This mode is used after the first installation of the unit or if the unit shuts down because the fuel tank ran out of thediesel.

 

YES


 

YES


 

Pumping frequency

-

 

6 Hz

 

Pumping flow

-

 

7.92ml / minute (5kW version)

 

Auto-ignition

N/A


 

The fuel pumping mode can only be done while the fuel line is disconnected from the heater unit or you visually control the position of the diesel on the transparent fuel line.


You must manually stop this mode before the fuel reaches the fuel inlet of the heating unit, otherwise the burner will be fulfilled with the fueland the next startup will be unsuccessful.

 

YES


 

The fuel pumping mode is fully automatic with extra high frequency allowing to prime the fuel line quickest possible.


As the heater unit automatically activates the glow plug before innitiating the fuel pumping mode there is no risk of overfilling the heater unit. 

 

Clock & Timer

 

Clock

YES

 

N/A

 

Timed startup

YES

Countdown set in relative values of hours and minutes

 

N/A

 

Timed shut-down

YES

Countdown set in relative values of hours and minutes

 

N/A

 

Voice-over

 

N/A


 

YES


 

Modes

N/A

 

Voice

Beep

Quiet mode

 

Language of voice mode

N/A

 

English

Chinese

Russian

 

Display

 

Display

Super brigh colour
graphical LED display

 

Super bright colour

graphical LCD display

 

Sleep mode

YES

 

N/A

 

Displayed values

 

Heating power

YES

(represented as pump frequency)

 

YES

 

Preset temperature

YES

 

YES

 

Error codes

YES

 

YES

 

Room temperature

YES

 

N/A

 

Heat exchanger temperature

YES

 

N/A

 

Voltage

YES

 

N/A

 

Altitude

YES

 

N/A

 

Status icons

 

Fan

YES

 

YES

 

Glow Plug

YES

 

YES

 

Fuel Pump

YES

 

YES

 

Combustion

YES

 

YES

 

Wireless controller

YES

 

YES

 

Timer

YES

 

N/A

 

Altitude adjustment

 

Pressure sensor allows autamatic djustment of the amount of the oxygen based on the altitude. This allows operating the heating unit up to 4000metres from sea level.

 

YES


 

YES


 

Technical specifications

 

User interface

3 buttons

 

Indefinite digital rotating knob with button

 

Speaker

N/A

 

YES

 

Temperature sensor

YES

 

YES

 

Connector

Round 3pin waterproof connector

 

Round 3pin waterproof connector

 

Hidden cords

YES

* going downwards OR backwards

 

N/A

* going downwards


 

Dimensions

 

Height

2.36 inches (60 mm)

 

1.89 inches (48 mm)

 

Width

3.07 inches (78 mm)

 

2.87 inches (73 mm)

 

Depth

0.59 inches (15 mm)

 

1.06 inches (27 mm)

 

Keychain wireless controller

 

YES

(optional)

* can be ordered separatelly

 

YES

(included)

 

Modes

 

Start up / Shut down

YES

 

YES

 

Fixed power mode adjustment

YES

 

YES

 

Thermostatic mode adjustment

YES

 

YES

 

Specifications

 

User interface

4 buttons

 

4 buttons

 

Connection

Radio communication

 

Radio communication

 

LCD wireless controller

 

YES

(included)

 

N/A

 

Modes

 

Start up / Shut down

YES

 

N/A

 

Fixed power mode adjustment

YES

 

N/A

 

Thermostatic mode adjustment

YES

 

N/A

 

Displayed VALUES

 

Heating power

YES

(represented as pump frequency)

 

N/A

 

Preset temperature

YES

 

N/A

 

Altitude

YES

 

N/A

 

Error codes

YES

 

N/A

 

Voltage

YES

 

N/A

 

Status icons

 

Fan

YES

 

N/A

 

Heat exchanger temperature

YES

 

N/A

 

Specifications

 

Display

Graphical colour LCD display

 

N/A

 

User interface

4 buttons

 

N/A

 

Language

English

Chinese

 

N/A

 

Connection

Radio communication

 

N/A